3 Replace the failed disk on the branch office server.
a Remove power from the down server.
b Remove the failed disk.
c Install the replacement disk.
d Apply power to the server.
e Press the start button on the front panel.
4 Log in as root and configure networking parameters on the down server
by entering this command:
vcx-config-network --wizard
Follow the instructions in
Messaging Server
5 If necessary, upgrade the software on the down server to match the
software version on the other servers in the VCX system.
a Compare the software version on the down server to the software
version on another VCX server.
On the down server and the other server, enter this command:
vcx-showversion
b If the down server is running an earlier software version than the other
branch office server, download the appropriate software upgrade file
to the
/opt/installtemp
The location of the software upgrade file depends on 3Com's service
delivery methods and on the customer network configuration.
Software upgrade file names begin with the software version and end in
a
extension (for example: vcx-x86-7.1.16c.tar). The examples in this
.tar
section assume that you need to upgrade to VCX 7.1.16c.
c Install the software upgrade file using these commands:
cd /opt/installtemp
tar xvf vcx-x86-7.1.16c
cd upgrade-7.1.16c
./install-upgrade
d Switch to the upgraded version of the software using this command:
vcx-switchversion --manual 7.1.16c
Normally the vcx-switchversion command is used with the --manual
option to downgrade to a previous software version. When you use it
in a disk replacement procedure, you can safely ignore this message:
Replacing a Disk (Branch Office)
Configuring a Branch Office IP Telephony and
in
Chapter
2.
directory on the down server.