420
A
B: R
PPENDIX
EPLACING A
F
D
VCX S
AILED
ISK ON A
b Enter these commands:
service vcxtomcat stop
2 On the Authentication and Directory server in the regional office that is
associated with this branch office, drop replication for the database for
this branch office.
a Log in as cworks.
b Enter these commands:
cd /opt/3com/VCX/vcxdata/bin
./dropReplication
c Enter the site ID for the branch office.
3 Replace the failed disk on the branch office server.
a Remove power from the down server.
b Remove the failed disk.
c Install the replacement disk.
d Apply power to the server.
e Press the start button on the front panel.
4 Log in as root and configure networking parameters on the down server
by entering this command:
vcx-config-network --wizard
If the down server is the primary VCX server, follow the instructions in
Configuring an IP Telephony Server at a Branch Office
5 If necessary, upgrade the software on the down server to match the
software version on other servers in the VCX system.
a Compare the software version on the down server to the software
version on another VCX server.
On the down server and on the other server, enter this command:
vcx-showversion
b If the down server is running an earlier software version than the other
server, download the appropriate software upgrade file to the
/opt/installtemp
The location of the software upgrade file depends on 3Com's service
delivery methods and on the customer network configuration.
ERVER
directory on the down server.
in
Chapter
3.