Panasonic FP-E Programming Manual page 1095

Fp series
Table of Contents

Advertisement

Table of system registers
C10, C14, C16, C32, T32 and SL1 in the table respectively indicate 10-point, 14-point, 16-point, 32-point
type and S-LINK type FP0 control units.
Add-
Item
ress
Alloca-
tion of
0
user
memory
5
6
Hold/
Non-
7
hold
8
14
20
23
Action
on error
26
27
Note) The setting values of the system registers No. 6, 7, 8 and 14 becomes invalid with the types other
than T32.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Name
Sequence program area
capacity
Timer and counter
division (setting of
starting counter number)
Hold type area starting
number setting for timer
and counter
(Available type: T32)
Hold type area starting
number setting for internal
relays (in word units)
(Available type: T32)
Hold type area starting
number setting for data
registers
(Available type: T32)
Hold or non-hold setting
for step ladder process
(Available type: T32)
Disable or enable setting
for duplicated output
Operation setting when an
I/O verification error
occurs
Operation setting when an
operation error occurs
Operation settings when
communication error
occurs in the remote I/O
(S-LINK) system
Default
value
The set values are fixed and cannot
be changed.
The stored values vary depending on
-
the type.
K3: 3K words (C10, C14, C16)
K5: 5K words (C32, SL1)
K10: 10K words (T32)
100
0 to 144
(K100)
(K0 to K144)
100
0 to 144
(K100)
(K0 to K144)
10
0 to 63 (K0 to K63)
(K10)
0
0 to 16384 (K0 to K16384)
(K0)
Non-hold
Hold (K10)
(K1)
Non-hold (K1)
Disable
Disable (will be syntax error) (K0)
(K0)
Enable (will not be syntax error) (K1)
Stop
Stop (K0)
(K0)
Operate (K1)
Stop
Stop (K0)
(K0)
Operate (K1)
Operate
Stop (K0)
(K1)
Operate (K1)
Descriptions
Set the system
registers 5 and 6 to
the same value.
5-7