Panasonic FP-E Programming Manual page 1250

Fp series
Table of Contents

Advertisement

FP2/FP2SH/FP10SH
Add-
Item
ress
Tool port
414
setting
412
413
COM
port
setting
414
415
416
417
General
commu-
nication
setting
418
5-162
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Name
Baud rate setting for the
tool port
Communication method
setting for COM port
Communication format
setting (Common setting
for both computer link
and serial data
communication)
When used for computer
link, the start and end
code settings of format
for MEWTOCOL-COM will
not be effective.
Available PLC: FP2/
FP2SH
Baud rate setting for the
COM port
Available PLC: FP2/
FP2SH
Unit number setting for
COM port
Available PLC: FP2/
FP2SH
Modem compatibility
setting for COM port
Available PLC: FP2/
FP2SH
Starting address setting
for received buffer of
serial data
communication mode
(data register number)
Capacity setting for
received buffer of serial
data communication
mode (word number)
Default
value
In the FP10SH, when the dip switch
SW1 on the CPU is off, the baud rate
setting is effective.
In the FP2/FP2SH, when the dip
switch SW1 on the rear of the CPU is
19200 bps
off, the baud rate setting is effective.
19200 bps 19200 bps
1200 bps 38400 bps
2400 bps 57600 bps
4800 bps 115200 bps
9600 bps
FP2: Not
UNUSED: COM port is not used.
used
COMPUTER LINK: computer link
FP2SH/
mode (when connecting C-NET)
FP10SH:
GENERAL: serial data communication
Computer
mode
link
Character
bit: 8 bits,
Parity chk:
"With,
Character bit: 7 bits/8 bits
odd"
Paritch chk: non/with odd/with even
Stop bit:
Stop bit: 1 bit/2 bits
1 bit,
End code: CR/CR+LF/NON/ETX
End code:
Start code: NO STX/STX
CR,
Start
code:
NO STX
19200 bps 19200 bps
1200 bps 38400 bps
19200 bps
2400 bps 57600 bps
4800 bps 115200 bps
9600 bps
1
1 to 99 (unit No. 1 to 99)
Modem enabled/Modem disabled
Modem
When connecting a modem, set the
disabled
unit number to 1 with system register
415.
FP2SH/FP10SH:
0
0 to 10240
FP2: 0 to 5999
1024
0 to 1024
Descriptions
For details about
its usage, refer to
the F144 (TRNS)/
P144 (PTRNS)
instructions.