Panasonic FP-E Programming Manual page 1254

Fp series
Table of Contents

Advertisement

FP1/FP-M/FP2/FP2SH/FP10SH/FP3
Address
R9009
Carry flag
R900A
> Flag
R900B
= Flag
R900C
< Flag
Auxiliary timer
contact
(Available PLC: FP-M
R900D
C20, C32/FP1 C56,
C72/FP2/FP2SH/FP3/
FP10SH)
Tool port error flag
R900E
(Available PLC: FP1/
FP-M/FP2SH/FP10SH)
Constant scan error
R900F
flag
R9010
Always on relay
R9011
Always off relay
R9012
Scan pulse relay
R9013
Initial on pulse relay
R9014
Initial off pulse relay
Step ladder initial on
R9015
pulse relay
R9016,
Not used
R9017
0.01 s clock pulse
R9018
relay
0.02 s clock pulse
R9019
relay
R901A
0.1 s clock pulse relay
R901B
0.2 s clock pulse relay
R901C
1 s clock pulse relay
5-166
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Name
Turns on for an instant,
- when an overflow or underflow occurs.
- when "1" is set by one of the shift instructions.
Turns on for an instant when the compared results become
larger in the "F60 (CMP)/P60 (PCMP),
F61(DCMP)P61(PDCMP),F62 (WIN)/P62 (PWIN) or F63
(DWIN)/P63 (PDWIN) comparison instructions."
Turns on for an instant,
when the compared results are equal in the comparison
-
instructions.
when the calculated results become 0 in the arithmetic
-
instructions.
Turns on for an instant when the compared results become
smaller in the "F60 (CMP)/P60 (PCMP),
F61(DCMP)P61(PDCMP), F62 (WIN)/P62 ,(PWIN) or F63
(DWIN)/P63 (PDWIN) comparison instructions."
Turns on when the set time elapses (set value reaches 0) in
the timing operation of the F137(STMR)/F183(DSTM)
auxiliary timer instruction.
Available PLC for F183 (DSTM) instruction: FP2/FP2SH/
FP10SH
The R900D turns off when the trigger for auxiliary timer
instruction turns off.
Turns on when communication error at tool port is occurred.
Turns on when the scan time exceeds the time specified in
system register 34 during constant scan execution.
Always on.
Always off.
Turns on and off alternately at each scan.
Turns on only at the first scan in the operation.
Turns off from the second scan and maintains the off state.
Turns off only at the first scan in the operation.
Turns on from the second scan andmaintains the on state.
Turns on for an instant only in the first scan of the process
the moment step ladder process is opened.
-
Repeats on/off operations in 0.01 s cycles.
Repeats on/off operations in 0.02 s cycles.
Repeats on/off operations in 0.1 s cycles.
Repeats on/off operations in 0.2 s cycles.
Repeats on/off operations in 1 s cycles.
Description