FP1/FP-M/FP2/FP2SH/FP10SH/FP3
Address
Sampling trace end
flag
R902D
(Available PLC: FP2/
FP2SH/FP3/FP10SH)
Sampling trigger flag
R902E
(Available PLC: FP2/
FP2SH/FP3/FP10SH)
Sampling enable flag
R902F
(Available PLC: FP2/
FP2SH/FP3/FP10SH)
F145 (SEND)/P145
(PSEND) and F146
(RECV)/P146 (PRECV)
R9030
instruction executing
flag
F145 (SEND)/P145
(PSEND) and F146
(RECV)/P146 (PRECV)
R9031
instruction end flag
(Available PLC: FP2/
FP2SH/FP3/FP10SH)
COM port mode flag
(Available PLC:
FP-M C20C, C32C/FP1
R9032
C24C, C40C, C56C,
C72C/FP2/FP2SH/
FP10SH)
F147 (PR) instruction
flag
(Available PLC:
R9033
FP-M C20, C32/FP1
C24, C40, C56,C72/
FP2/FP2SH/FP3/
FP10SH)
Editing in RUN mode
flag
R9034
(Available PLC: FP2/
FP2SH/FP3/FP10SH)
F152 (RMRD)/P152
(PRMRD) and F153
(RMWT)/P153
R9035
(PRMWT) instruction
execution flag
(Available PLC: FP2/
FP2SH/FP3/FP10SH)
5-168
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Name
Turns on when the sampling trace ends.
Turns on when the sampling trace trigger of the F156
(STRG)/P156 (PSTGR) instruction is turned on.
Turns on when the starting point of sampling is specified.
Monitors if CPU is in the F145 (SEND)/P145 (PSEND) and
F146 (RECV)/P146 (PRECV) instructions executable
condition as follows:
- off: None of the above mentioned instructions can be
executed.
- on: One of the above mentioned instructions can be
executed.
Monitors if an abnormality has been detected during the
execution of the F145 (SEND)/P145 (PSEND) and F146
(RECV)/P146 (PRECV) instructions as follows:
- off: No abnormality detected.
- on: An abnormality detected. (communication error)
The error code is stored in:
- FP3: DT9039
- FP2/FP10SH: DT90039
Monitors the mode of the COM port as:
- on: Serial data communication mode
- off: Computer link mode
Turns on while a F147 (PR) instruction is executed.
Turns off when a F147 (PR) instruction is not executed.
Turns on while editing a program in the RUN mode.
Monitors if FP3/FP10SH is in the F152 (RMRD)/P152
(PRMRD) and F153 (RMWT)/P153 (PRMWT) instructions
executable condition as follows:
- off: None of the above mentioned instructions can be
executed.
- on: One of the above mentioned instructions can be
executed.