IR-Erasure Width
Requirement
A
▲
A
▲
A
1171D062AA
NOTE
• This adjustment must be made when a shadow is produced from the Original Scale.
Adjustment Procedure
1. Call the Tech. Rep. Mode to the screen.
2. Touch "Tech. Rep. Choice".
3. Touch "IR-Erasure Width" to call up the IR-Erasure Width adjustment function.
4. Press the Clear key to clear the current setting value.
5. Enter the new setting value from the 10-Key Pad.
Setting Instructions
To make the erase width along the four edges of the paper (width A) smaller, decrease the
setting value.
To make the erase width along the four edges of the paper (width A) greater, increase the
setting value.
Setting Value
6. Touch "END" to validate the setting value.
NOTE
• Be sure to touch "END" to return to the normal operating mode. If the Panel Reset key is
used, the previous setting remains valid.
Set the erase width along the four edges of the paper
(width A) in the range between 0 and 3 mm.
A
Adjust Mode
IR-Erasure Width
1171D301CA
D-53
Setting Range
0 to 3
Use to clear
setting value.
Use to enter setting value.
1167D069AA