FrameMaker Ver.5.5E(PC) Di200/Di251/Di351 DIS/REASSEMBLY, ADJUSTMENT
01.02.09
(6)
Registration (FD) (Printer)
Requirement
A
4011D097AA
Specification
10 ±2.0 mm
: U.S.A. and Canada Only
NOTE
• This adjustment must be made when the PH Unit has been replaced and after Registra-
tion (CD) (Printer) has been made.
Adjustment Procedure
1. Call the Adjust Mode to the screen.
2. Touch "Printer" and "Registration (FD)", in that order.
3. Touch "Test Print".
4. Press the Start key.
Paper will be fed from the 1st Drawer and a test pattern will be produced.
5. Check to see if width A on the test pattern meets the specifications.
If width A falls outside the specified range, perform the following steps for adjustment.
6. Touch "END" to recall the Registration (FD) screen.
7. Press the Clear key to clear the current setting value.
Adjust so that width A on the test pattern output falls
within the following range.
Adjust Mode
20
( )/
Registration (FD)
35-cpm copier: -19 to +19
D-43
Setting Range
25-cpm copier: -26 to +26