C10XX to C13XX

• These malfunctions are concerned with faulty symptoms as they mainly relate to soft-
ware, hardware, and communications.
Code
C1038 1. Check the connection between Master Board and MFB2 Board.
2. Reset the malfunction and turn OFF and ON the Power Switch.
3. Change MFB2 Board. Change Master Board.
C1300 1. Reset the malfunction and turn OFF and ON the Power Switch.
2. Check the connection between PH Assy and Master Board.
3. Change PH Assy. Change Master Board.
C133A 1. Reset the malfunction and turn OFF and ON the Power Switch.
2. Check the connection between each of the following and Master Board.
A. 2nd Drawer paper source unit
B. 3rd Drawer paper source unit
C. 4th Drawer paper source unit
D. 5th Drawer paper source unit
E. OT-102
F. JS-201
3. Disconnect the connection between the copier and A to F and then turn OFF
and ON the Power Switch.
→ If the malfunction code display persists, change Master Board.
→ If the malfunction is no longer detected, connect the connectors sequen-
tially and turn OFF and ON the Power Switch. When "C133A" is detected,
check the connector of the corresponding paper source unit and, if it is
intact, change the PWB-A of the unit.
C133B 1. Reset the malfunction and turn OFF and ON the Power Switch.
2. Check the connection between Master Board (copier) and Control Board
(Finisher).
3. Unplug the connector between Master Board and Control Board and turn
OFF and ON the Power Switch.
→ If the malfunction code display persists, change Master Board.
→ If the malfunction is no longer detected, change Control Board.
C13C0 1. Reinstall I/C, reset the malfunction, and turn OFF and ON the Power Switch.
2. Check the connection between I/C fuse and Master Board.
3. Change Master Board.
C13D0 1. Reset the malfunction, turn OFF and ON the Power Switch, and unplug the
power cord and plug it back in.
2. Check the connection between IC3 of Master Board and EEPROM.
3. Change Master Board.
4. Change EEPROM.
For the precautions to be observed when changing the EEPROM, see DIS/
REASSEMBLY, ADJUSTMENT.
C13F0 1. Reset the malfunction and turn OFF and ON the Power Switch.
2. Check the connection between PH Assy and Master Board.
3. Change PH Assy. Change Master Board.