Administrator # Input; Counter - Minolta Di200 Service Manual

Hide thumbs Also See for Di200:
Table of Contents

Advertisement

FrameMaker Ver5.5E(PC) Di200/Di251/Di351 SWITCHES ON PWBs/TECH. REP. SETTINGS
01.01.26
Touch Panel
Display
Machine
Displays the machine configuration status.
Configuration
Technical Memo
Enter the serial number and other data.
Original Size
Select "ON" when the optional Original Size Detecting Sensor is
Detecting
mounted.
Option
(3)

Administrator # Input

• Set an ID number for opening the "Admin. Management Mode" screen of Utility Mode
from the 10-Key Pad.
(4)

Counter

• Shows the number of copies made on each paper size or type.
<Clearing a Count>
1. Open the counter menu screen.
2. Select the counter to be cleared.
3. Press the Clear key.
4. Touch "END".
Press the Interrupt key to undo the clearing operation, restoring the original count.
"I/C Life 1" and "I/C Life 2" of "PM" cannot be cleared. They are automatically reset
when a new I/C is installed.
<Clearing All Counts of a Counter Type at Once>
1. Touch the "Counter Reset" key.
2. Select the counters to be cleared all at once.
3. Touch "OK".
Touch Panel
Display
Paper
Counts the number of sheets of paper used according to the size and
type.
Setting (The default is
ON
Setting
Paper size
A3
11 x 17
B4
11 x 14
A4
Letter
B5
Legal
A5
Exec.
FLS
5-1/2 x 8-1/2
S-22
Highlighted
).
OFF
Paper Type
Normal
Recycle
Special
Not for 2-sided