Minolta Di200 Service Manual page 125

Hide thumbs Also See for Di200:
Table of Contents

Advertisement

FrameMaker Ver5.5E(PC) Di200/Di251/Di351 SWITCHES ON PWBs/TECH. REP. SETTINGS
01.01.26
Mode
7
416
Bit:
0
Bit
Function
7
Sound Volume Setting 3 Monitor
Tone (copy)
6
5
4
Orientation Of Images When Fin-
isher Is Connected (copy)
3-2
1
Overseas Scanner File Format
0
Disable Auto Shut Off
Mode
7
417
Bit:
0
Bit
Function
7
Max Copy Sets
6-0
Set Copy Quantity Limit (copy)
Initial value
6
5
4
3
2
1
0
1
1
0
0
0
0
0
Logic
0
1
0
Bit3-1:
000
(No tone)
001
1
010
2
011
3
100
4
101
5
Setting
Other
inhibit
Not
Facing
Sets the orientation of the image when a fin-
facing
each
isher is connected.
each
other
other
Fixed
Setting change inhibit
TIFF
PDF
Sets the file format used with an overseas
scanner. (For maintenance use by the admin-
istrator)
NO
YES
Setting that enables or disables to select "Dis-
abled" setting for Auto Shut Off function.
Initial value
6
5
4
3
2
1
0
1
1
0
0
0
1
1
Logic
0
1
Setting for placing or not placing an input limit
OFF
ON
on the copy quantity
Bit6-0:
Setting
0000000
inhibit
0000001
1
1100011
99
Setting
Other
inhibit
S-48
HEX: 60
Description
Line monitor tone volume setting
HEX: 63
Description
Sets the limit quantity when Max.
Copy Sets of MODE 417 Bit 7 is
set to "Yes".