Minolta Di200 Service Manual page 119

Hide thumbs Also See for Di200:
Table of Contents

Advertisement

FrameMaker Ver5.5E(PC) Di200/Di251/Di351 SWITCHES ON PWBs/TECH. REP. SETTINGS
01.01.26
Mode
7
404
Bit:
0
Bit
Function
7
Auto Panel Reset
6
5
4
3
2
1
0
Mode
7
405
Bit:
0
Bit
Function
7
Energy Save Mode
6
5
4
3
2
1
0
Initial value
6
5
4
3
2
1
0
0
0
0
0
0
0
1
Logic
0
1
Bit7-0:
00000000
No Reset
00000001
1 min.
11110000
240 min.
11111111
30 sec.
Other
Setting
inhibit
Initial value
6
5
4
3
2
1
0
0
0
0
1
1
1
1
Logic
0
1
Bit7-0:
Setting
00000000
inhibit
00000001
1 min.
00001111
15 min.
11110000
240 min.
Setting
Other
inhibit
S-42
HEX: 01
Description
Setting of whether or not auto
clear takes place after the speci-
fied time from the end of copying
or a key operation and also the
time setting.
1-minute steps
HEX: 0F
Description
Setting of auto preheat time after
the specified time from the end of
copying or a key operation.
1-minute steps

Advertisement

Table of Contents
loading

This manual is also suitable for:

Di251Di351