Mitsubishi Q01CPU User Manual page 624

Melsec-q series, qcpu
Hide thumbs Also See for Q01CPU:
Table of Contents

Advertisement

12
TROUBLESHOOTING
Number
Name
SM1760
SM1761
SM1762
SM1763
SM1764
SM1765
SM1766
SM1767
Transfer trigger
completion flag
SM1768
SM1769
SM1770
SM1771
SM1772
SM1773
SM1774
SM1775
(16)Redundant power supply module information
Number
Name
Power supply off
SM1780
detection flag
Power supply failure
SM1781
detection flag
Momentary power
SM1782
failure detection flag
for power supply 1 *1
Momentary power
SM1783
failure detection flag
for power supply 2 *1
*1: The "power supply 1" indicates the redundant power supply module (Q64RP) mounted on the POWER 1 slot of the redundant base unit (Q38RB/Q68RB/
Q65WRB).
The "power supply 2" indicates the redundant power supply module (Q64RP) mounted on the POWER 2 slot of the redundant base unit (Q38RB/Q68RB/
Q65WRB).
*2: The module whose first 5 digits of serial No. is 04012 or later.
However, for the multiple CPU system configuration, this applies to all CPU modules whose first 5 digits of serial No. are 07032 or later.
12
- 300
12.7 Special Relay List
Table12.42 Special relay
Meaning
SM1760
SM1761
SM1762
SM1763
SM1764
SM1765
SM1766
OFF : Transmission
SM1767
uncompleted
SM1768
ON
: Transmission end
SM1769
SM1770
SM1771
SM1772
SM1773
SM1774
SM1775
Table12.43 Special relay
Meaning
• Turns ON when one or more redundant power
OFF : No redundant power
supply modules with input power OFF are detected.
supply module with
• Turns on if any of SD1780 bits is on.
input power OFF
• Turns off if all bits of SD1780 are off.
detected
• Turns OFF when the main base unit is not the
ON : Redundant power
redundant main base unit (Q38RB).
supply module with
0: communication with peripheral device is executed
input power OFF
1: communication with peripheral device is
detected
nonexecuted
• Turns ON when one or more faulty redundant power
supply modules are detected.
OFF : No faulty redundant
• Turns on if any of SD1781 bits is on.
power supply module
• Turns off if all bits of SD1781 are off.
detected
• Turns OFF when the main base unit is not the
ON : Faulty redundant
redundant main base unit (Q38RB).
power supply module
0: communication with peripheral device is executed
detected
1: communication with peripheral device is
nonexecuted
• Turns ON when a momentary power failure of the
input power supply to the power supply 1 or 2 is
detected one or more times. After turning ON,
remains ON even if the power supply recovers from
the momentary power failure.
• Turns OFF the flag (SM1782, SM1783) of the power
OFF : No momentary power
supply 1/2 when the CPU module starts.
failure detected
• When the input power to one of the redundant power
ON : Momentary power
supply modules turns OFF the corresponding flag
failure detected
turns OFF.
• Turns OFF when the main base unit is not the
redundant main base unit (Q38RB).
0: communication with peripheral device is executed
1: communication with peripheral device is
nonexecuted
Explanation
Block 49
Block 50
Block 51
Block 52
<In the case of Q4AR>
Block 53
Turns ON only during one
Block 54
scan when the transmission
of the corresponding data is
Block 55
completed.
Block 56
Block 57
<In the case of QnPRH>
Block 58
Turns ON only during one
Block 59
scan when the transmission
of the corresponding block is
Block 60
completed.
Block 61
Block 62
Block 63
Block 64
Explanation
Corres-
ponding
Set by
Corresponding
ACPU
(When Set)
M9
S (status change)
New
Corres-
ponding
Set by
Corresponding
(When Set)
ACPU
M9
S (Each END)
S (Each END)
New
S (Each END)
CPU
Q4AR
QnPRH
CPU
Qn(H)*2
QnPH*2
QnPRH
Rem