LOADING AND INSTALLATION
10.4 How to Set Stage Numbers for the Extension Base Unit
When using two or more extension base units, their stage numbers must be set with their
stage number setting connectors.
(The number of extension stages is set to 1 by factory default.)
Make this setting in the following procedure.
*1
* 1: Since the Q6 WRB is fixed to the first extension stage, extension stage No. setting is not
required.
1) The stage number setting connector of the extension base unit is located
under the IN side base cover. (Setting of the extension number setting connec-
tor (
Section 6.1.3))
First, loosen the upper and lower screws in the IN side base cover and remove
the base cover from the extension base unit.
Fixing screw
Extension base unit
Flat blade screwdriver
Base cover
Diagram 10.29 Removing a base cover
2) Insert the connector pin in the required stage number location of the connector
(PIN1) existing between the IN and OUT sides of the extension cable
connector.
Connector pin
Diagram 10.30 Setting the number of extension stages
10.4 How to Set Stage Numbers for the Extension Base Unit
Base cover