12
TROUBLESHOOTING
Error code
Error item
(Hexadecimal)
4184
H
4185
H
4186
H
4187
H
4188
H
4189
H
418A
H
418B
H
418C
H
418D
H
418E
H
Ethernet
418F
H
I/F
4190
H
Error
4191
H
4192
H
4193
to
H
4196
H
4197
H
4198
H
4199
H
419A
H
419B
H
419C
H
419D
H
419E
H
12
- 232
12.3 Error Code List
12.3.11 Error codes returned to request source during communication with CPU module
Table12.12 Error code
Error details
System error (The buffer in OS is abnormal.)
System error (The connection processing in
OS is abnormal.)
System error (The argument data in OS is
abnormal.)
System error (The wait processing in OS is
abnormal.)
System error (The data length in OS is
abnormal.)
System error (The protocol information in OS
is abnormal.)
System error (The address data of
communicating module in OS is abnormal.)
System error (The protocol information in OS
is abnormal.)
System error (The protocol specification
processing in OS is abnormal.)
System error
(The typed data in OS is abnormal.)
System error (The expedited data processing
in OS is abnormal.)
System error (The protocol information in OS
is abnormal.)
System error (The address data of
communicating module in OS is abnormal.)
System error (The host module address
processing in OS is abnormal.)
System error (The transmission processing in
OS is abnormal.)
System error (The connection processing in
OS is abnormal.)
System error (The connection termination
processing is abnormal.)
System error (The connection processing in
OS is abnormal.)
System error (The connection termination
processing is abnormal.)
System error (The processing order in OS is
abnormal.)
Connection to the module was unsuccessful
or interrupped.
Corrective action
• Check whether the power module and programmable
controller CPU are attached properly.
• Check whether the system use environment is within
the range of the programmable controller CPU
genaral specifications.
• Check whether the power capacity is sufficient.
• Reset the CPU module.
If the error is shown once again, the CPU module
hardware is abnormal. Please contact with system
service, agency, or branch office nearby and tell the
problems.
• Check the receiving module operation.
• Check the status of the lines such as a cable, a hub
and a route to receiving modules
• Retry to connect a little while later, if the error occured