3.13 TME1 Serial Cable

The TME1 serial cable (C39195-A9700-B532-*) is used for connecting to a PC or mo-
dem in order to program the system using the HiPath 1100 E1 Trunk Manager tool.
MB
9-pin male
Mini DIN connector
9
7
6
3
2
1
1 = DCD
6 = DSR
2 = RX
7 = RTS
3 = TX
8 = CTS
4 = DTR
9 = RI
5 = GND
Figure 3-39
Serial cable connection to TME1
TME1 serial cable signals
Table 3-38
TME1 serial cable signals
Pin
DCD
CTS
DSR
DTR
GND
RTS
RX
TX
RI
A31003-K1250-S100-12-7619
HiPath 1100, Service Manual
Length: 9.8 feet (3 meters)
1 = DCD
2 = RX
3 = TX
4 = DTR
5 = GND
6 = DSR
7 = RTS
8 = CTS
9 = RI
Signal
Date Carrier Detect
Clear To Send
Date Send Ready
Date Station Ready
Ground
Request To Send
Receive Data
Transmit Data
Ring indicator
1 = DCD
2 = RX
3 = TX
4 = DTR
5 = GND
6 = DSR
7 = RTS
8 = CTS
9 = RI
Modules
TME1 Serial Cable
PC
Modem
9-pin female
SubD connector
5 GND
RI 9
4 DSR
RTS 8
3 RX
CTS 7
2 TX
DTR 6
1 DCD