Siemens hipath 1100 Service Manual page 76

Hide thumbs Also See for hipath 1100:
Table of Contents

Advertisement

Modules
Power Supply Unit (PSU)
PSU Connector Assignments (HiPath 1120)
PSU Interfaces CND, RSA and SPA
Figure 3-28
PSU Connector Assignments (HiPath 1120) - CND, RSA and SPA
Warning
!
Turn the system power ON or OFF by means of the supply's power cable or the in-
put circuit breaker.
3-44
Table 3-32
Contacts
1 - 2
3 - 4
5 - 6
HiPath 1120 System PSU Connector - CND, RSA and SPA
Table 3-33
PSU Connector Assignments HiPath 1120 - CND, RSA and SPA
Contacts
CND
1
Free
2 - 3
8 V
4 - 5
23 V
6 - 7
65 V
8 - 9
45 V
10
Ground
PSU Connector Assignments - HiPath 1120
Function
8 V
rms
23 V
rms
40 V
rms
1 ......................... 10
Function
RSA
SPA
Free
Free
8 V
8 V
rms
rms
23 V
23 V
rms
rms
42 V
65 V
rms
rms
Free
Free
rms
Free
Free
For internal distribution only
rms
rms
rms
A31003-K1250-S100-12-7619
HiPath 1100, Service Manual