Installation
Installation of Expansion and Option Modules
4.6.2 Installing Modules
On the HiPath 1120
●
Installation Procedures
Step
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
On the HiPath 1130/1150
●
Installation Procedures
Step
1.
2.
3.
4.
5.
6.
7.
4-22
Procedure
Turn off the power supply.
Remove the system's cover
Insert the module into one of the slots shown in Figure 4-16.
Connect the module to the MOB using the flat cable on the top slot.
In the CND version, the EB module and the motherboard must be con-
nected using a power/connection cable.
To install on the bottom slot lift the top slot and use the pin connector to
make the connection.
Connect to module connectors (see Figure 4-27).
Reassemble the entire set.
"Performing a Visual Inspection" on page 4-48.
Turn on the power supply.
Configure the required data (see "Operation" on page 6-1).
Procedure
Remove the power supply.
Remove the backplane.
Insert the module into one of the slots shown in Figure 4-18.
Reassemble the entire set.
"Performing a Visual Inspection" on page 4-48.
Turn on the power supply.
Configure the required data (see "Operation" on page 6-1).