Installation

Performing a Visual Inspection

System telephones are powered through the C and D wires. Take the necessary
precautions to avoid short circuits at the interconnect block.
If a short circuit occurs between wires C and D, the interface's protection will take
the extension out of service. To activate the extension again, remove the short, dis-
connect the system telephone then reconnect it. The interface should start operat-
ing normally now.
With 2-wire analog telephone sets (A, B) there is no problem in the event of a mo-
mentaryshort circuit.
The maximum distance for installing a system telephone using a two-pair cable with
2
a 0.4 mm
imum distance is 1.5 miles (2,500 meters).
4.16 Performing a Visual Inspection
Introduction
Before starting up the system, perform a visual inspection of all hardware, cables and
power supply. This procedure should be performed with the entire system turned
OFF .
Warning
!
Before starting to work on the HiPath 1190, make sure the system is grounded and
disconnected from all power sources.
Follow all guidelines to protect the system from electrostatic discharge (see "Safety
Information: Caution" on page 1-5).
Visual Inspection Procedure
Table 4-8
Visual Inspection Procedure
Step
1.
Compare the installation position
of modules on the slots against
the installation diagram.
Check to see that all modules are
2.
securely and properly attached.
3.
Check the network's line voltage. Multimeter.
4-48
copper wire is 0.3 miles (500 meters). For Standard Telephones the max-
Procedure
Aids/
Notes
Module Installation
Diagram.
See "System Data"
on page 2-1.
For internal distribution only
Measure
Make the appropriate cor-
rections
to the modules and notify
the appropriate person.
Attach or secure modules
as needed.
Verify voltage at power
source.