Siemens hipath 1100 Service Manual page 209

Hide thumbs Also See for hipath 1100:
Table of Contents

Advertisement

For internal distribution only
External analog line seizure protocol (017)
This feature specifies the protocol to be used by the system for seizing an external
analog line, based on the local carrier's information.
ID for Analog Lines (005)
Enabled by the local Carrier, this service provides Caller ID over FSK and DTMF pro-
tocols on analog lines.
When a Country setting is specified, the appropriate protocol is automatically select-
ed.
External Line Call Direction (55)
Specifies how to access external lines when receiving or making a call.
An external line can be:
1 = Bi-directional
2 = Incoming unidirectional
3 = Outgoing unidirectional
Flash Duration (18)
Specifies the time during which the Flash signal remains active on the external analog
line in relationship to the detection defaults set at the exchange.
Reseizure Timeout for an External Line (29)
This setting specifies the timeout to reseize the external line after a call has been
completed.
Maximum time between rings for an incoming call (17)
This setting defines a time interval of approximately 6 seconds between two pulses
transmitted by the local carrier. At the end of this time interval, the system discon-
nects from the external line and gets ready to receive other calls.
Coefficient for an external analog line (47)
This function couples the impedances for a system and the public network external
analog line to which it is connected.
A31003-K1250-S100-12-7619
HiPath 1100, Service Manual
Configuring the System Specifically for the Client
Comments about the System's Programming Codes