For internal distribution only
Connections
Figure 4-34
Red wire (R) = voice (extension's B wire).
Green wire (G) = voice (extension's A wire).
Black wire (BK) =CD card's C wire (positive in relation to D).
Yellow wire (Y) =CD card's D wire (negative in relation to C).
Installation Procedures
Step
1.
2.
3.
4.
5.
6.
A31003-K1250-S100-12-7619
HiPath 1100, Service Manual
Connections for telephone jacks (for Brazil)
Procedure
Install telephone jacks at the extensions.
Connect each extension jack to the desired a/b slot on the Main Distribu-
tion Frame.
System telephones are preset at factory default for C/D pairs.
If you need to select a different C/D pair, see Figure 4-27 or Figure 4-29
then program the new C/D interface assignment.
Install the telephone sets.
"Performing a Visual Inspection" on page 4-48.
Configure the required data (see "Operation" on page 6-1).
Installation
Installing Telephone Terminals