Mitsubishi Electric GT1695M-XTBD User Manual page 446

Got1000 gt16 series graphic operation terminal
Hide thumbs Also See for GT1695M-XTBD:
Table of Contents

Advertisement

Error
code
PLC cannot handle as
448
requested. Correct
devices.
Dedicated device is out of
449
range. Confirm device
range.
Path has changed or
450
timeout occurred in
redundant system.
Q redundant system
451
settings and current
config. do not match.
460 Communication unit error
Communication channel
480
not set. Set channel
number on Utility.
Communication unit not
481
mounted to the slot of
active channel.
Too many same units are
482
mounted. Confirm the no
of units.
Simultaneous mounting of
483
the units are not allowed.
16
16.3 Error Message and System Alarm
- 25
16.3.2 List of error message/system alarm
Error message
A device outside the range of QnACPU file registers and the
buffer memory was specified.
Correct the monitor device by setting file register of the PLC
CPU.
1. Set the address for the special function module in the
2. Set the device in the GOT monitor available range.
The path has been switched or timeout occurred in the
redundant system.
1. Check the PLC CPU to know if the path has been
2. Check the cable connection status, the communication
3. This error may occur when the load of the PLC CPU
4. Perform one of the following operations if the PLC
Change the Q redundant setting in accordance with the actual
Q redundant CPU system.
1. Reset the power of the GOT.
2. Replace the unit.
Channel (CH.No.1 to 4) to communicate with a controller is
not set.
1. After setting the Communication Settings on the GT
2. Change the channel assignment in the Communication
The interface where the channel (CH No.1 to 4) is set does
not have a communication unit installed.
1. Install a communication unit to the interface where the
2. Change assignment of the channel (CH No.1 to 4) in the
Units are mounted on the GOT exceeding the maximum
number of mountable units.
Check the number of units, and remove unnecessary units.
Two or more units which cannot be mounted on the GOT
simultaneously are mounted.
Check the mounted units, and remove unnecessary units.
Action
GOT monitor available range.
switched.
unit installation status, and the PLC CPU status.
becomes heavier when accessing other stations. In such
a case, transfer the data of the other stations to the host
station PLC CPU and monitor them at the host.
scanning time is long: COM instruction/Extension of END
processing/Setting of the number of processing times for
general data/Data update batch processing.
Designer2, download it to the GOT.
Setting on the utility.
channel (CH No.1 to 4) is set.
Communication Setting.
Channel
No.
storage
*1
*1
*1
*1