Error
Error message
code
Warning! Built-in Flash
509
ROM needs replacement.
Change the GOT.
Clock data input out of
510
range
Insufficient Flash ROM
520
capacity
Insufficient user memory
521
(RAM) capacity
Unnecessary file deleted
522
to create new file.
Device writing error.
524
Correct device.
Unable to read/write
525
alarm log files under
different projects.
526 File conversion failed.
Error in SRAM.
528
Failed to write data.
Data error in SRAM.
529
Check the battery life.
Improper monitor device.
530
Confirm monitor channel.
535 Cannot open image file.
Image file error or invalid
536
file format.
Action
The dedicated GS is notifying that the built-in flash memory
writing times have reached the set times or more.
The GOT must be replaced. In that case, Data backup and re-
setting are needed. The GOT can also be restored by turning
off the notification signal manually. In such a case, turn it OFF
after setting a value greater than the addition times.
The value that is input as clock data is out of the input
enabled range.
In this case, the input value is not accepted.
Confirm the input range of the value to be input as clock data,
and input the proper value again.
The capacity for the buffering area is insufficient in the build in
flash memory
1. Confirm whether there are no mistakes in specified
buffering area size.
The capacity for the buffering area is insufficient in the user
memory (RAM)
1. Confirm whether there are no mistakes in specified
buffering area size.
The old file of different contents has been deleted and a new
file has been created.
Note that the old file is deleted and the new file is created if
the file of the same name with different contents exists when
creating files.
When writing in the device, error occurred.
Correct the device.
Unable to read the alarm log file saved by the different
project.
Confirm where to store the alarm log file and alarm log file.
The file specified for the file conversion does not exist.
Check the settings for specifying a file to be converted.
The error may be caused by a failure in the GOT main unit.
Please consult your local Mitsubishi (Electric System) Service
center or representative.
Error in SRAM data due to battery voltage low, etc.
Confirm the battery status.
The channel of the specified monitor target does not exist or
the channel is not the monitor target.
Confirm the monitor target channel of the screen data.
Confirm whether any file exists in the CF card or USB
memory.
1. Confirm whether image files in the CF card or USB
memory are normal.
2. Confirm whether any image file of invalid format is stored.
16.3 Error Message and System Alarm