Mitsubishi Electric GT1695M-XTBD User Manual page 270

Got1000 gt16 series graphic operation terminal
Hide thumbs Also See for GT1695M-XTBD:
Table of Contents

Advertisement

(c) Data link information
Displays the MELSECNET/H communication unit data link information (communication status,
cause of communication suspension, cause of communication stop).
No.
(4)
Com Status
(5)
Cause of Ssp
(6)
Cause of Stop
(d) Transient status
Displays the number of transient transmission errors and the error code.
No.
(7)
Transmission Err
(8)
ErrCode
12
12.1 Diagnostic Functions
- 23
12.1.8 Network status display
Item
Displays the communication status of the host.
D-Link in prog.
D-Link Stop(A)ss
D-Link Stop (H)
B-Pass exec (No Area)
B-Pass exec (Param Err)
B-Pass exec (Param unreceived)
Disconnect (No B-Pass)
Disconnect (Line Err)
Testing
Reset. in prgr.
Displays the cause of disabled communication (transient transmission) of the host.
Normal Comm
Offline
Offline test
Initialize
Change Ctrl Sta
Testing Online
Baton Missing
Baton Duplicated
Dup Sta No
Dup Ctrl Sta
Rcv Retry Err
Send Retry Err
Time Out Err
Abnormal Line
Disconnection
No Own Sta Baton
Other (error code)
Displays the cause of disabled data link (cyclic transmission) of the host.
Normal
StopOrder
No Shared Param
Bad Shared Param
Bad Self Sta CPU
Com Aborted
Item
Description
: FData link being executed
: Cyclic transmission stopped from other station
: Cyclic transmission stopped by host
: Host B/W send no allocation
: Error in host parameters
: Common parameters not received
: Station numbers duplicated, cable not connected
: Cable not connected
: Testing online/offline
: Hardware failure
: Communicating normally
: Offline
: Testing offline
: Error (error code: F101, F102, F105)
: Error (error code: F104, F106)
: FError (error code: F103, F109, F10A)
: Error (error code: F107)
: Error (error code: F108)
: Error (error code: F10B)
: Error (error code: F10C)
: Error (error code: F10E)
: Error (error code: F10F)
: Error (error code: F110)
: Error (error code: F112)
: Error (error code: F11B)
: Error (error code: F11F)
: Error (error code: displayed)
: Communicating normally
: Cyclic transmission of all stations stopped from
: Parameters cannot be received
: Set parameter error
: A medium/critical error occurred in the host CPU
: Host data link error occurred
Displays the number of transient transmission errors.
Error histories of 16 errors are displayed in 16 lows from the latest.
host or other station
Description

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gt1685m-stbaGt1685m-stbdGt1695m-xtba

Table of Contents