Auto Stop Magnet Replacement; About; Procedure - Precor GEN06 Series C952 Service Manual

Table of Contents

Advertisement

Auto Stop Magnet Replacement

About

This procedure provides instruction to remove and replace the Auto Stop Magnet.

Procedure

Review entire procedure before starting.
CAUTION: Do not place the Auto Stop Magnet on or near a steel structure. If the
magnet assembly comes in contact with a steel structure and then pulled away from
the steel structure, the magnet can become dislodged from the magnet assembly
housing. Contact PRECOR customer service for repair or replacement.
1. Set the treadmill circuit breaker to OFF and unplug the treadmill's power cord.
2. Remove the front hood.
3. Remove the left and right trim strips from the treadmill deck.
4. Remove the four mounting bolts and two top plates that fasten the running deck to the
pivot bracket at the back of the treadmill. Keep fasteners for installation.
5. Pull the running deck out from the right side of the treadmill just far enough to expose
the front right edge of the running deck, see
6. Pry out the two push fasteners from the deck using a flat head screw driver and remove
the Auto Stop Magnet. Keep fasteners for installation.