No Power To The Console Troubleshooting - Precor GEN06 Series C952 Service Manual

Table of Contents

Advertisement

No Power to the Console Troubleshooting

Applies To: P10, P20, or P30 consoles only.
This procedure only applies to treadmill powered consoles.
1. Verify that the treadmill input power is correct, see
page 93.
2. Remove the treadmill hood and measure the AC voltage at the input side of the line fil-
ter. Verify that line voltage is present when the breaker switch is turned on.
a. If NO, replace the breaker switch.
b. If Yes, continue troubleshooting.
3. Measure the AC voltage at the output side of the line filter. Verify that line voltage is
present when the breaker switch is turned on.
a. If NO, Replace the line filter.
b. If Yes, continue troubleshooting.
4. Use a known good console and communication cable. Plug the test console and test
communications cable into the suspect treadmill lower control module (IFT drive). Does
the test console power up?
a. If NO, replace the lower control module (IFT drive).
b. If Yes, continue troubleshooting.
4. If the test console powered up, re-connect the test communications cable from the test
console to the original console. Does the original console power up?
a. If Yes, replace the Communications Cable.
b. If No, replace the upper PCA.
CAUTION: Swapping a lower control module from a good unit into a bad unit could
damage the lower control module from the good unit. If the control module that is
being swapped may have a defect and could damage components in the good unit.