Auto Stop Troubleshooting - Precor GEN06 Series C952 Service Manual

Table of Contents

Advertisement

Auto Stop Troubleshooting

This procedure will provide troubleshooting steps for the Auto Stop feature
Related Error Codes
Auto Stop error codes: 60, 61.
Refer to the
Error Code Troubleshooting Guide
information.
Procedure:
1. If the Console message is "Temporarily Out of Order" on the P80 console or "Please
use another Treadmill" on the P10, P20, or P30 console go Run Hardware Validation
Tests below.
2. Check the treadmill to ensure the Auto Stop hardware is installed.
If the Auto Stop hardware is not installed, contact Precor customer support to see
l
if your treadmill is compatible for the Auto Stop or arrange the installation of the
Auto Stop hardware.
3. Verify that the Auto Stop cable is plugged into the correct port in the console. The con-
nector for the Auto Stop is the same number of pins as the connector for the heart rate
grips, and you need to make sure that they were not reversed.
a. If the cables were reversed, swap the connectors and re-test.
b. If the cables were correctly connected, continue
4. If the Auto Stop hardware is installed, access the club settings and check if the Auto
Stop feature is enabled. If it is not enabled, enable the feature, see
Settings (5651565)" on
Run Hardware Validation Tests
5. Access the service access software Hardware Validation Tests (see
idation - Diagnostic Tests (51765761)" on page 13
feature is enabled the P80 Auto Stop sensor test will count the number of times the mag-
net crosses the sensor. The P10, P20, or P30 consoles will display USER DETECTED
if motion is detected from the running deck or NO USER DETECTED if no motion is
detected from the running deck. If the unit passes this test or a USER DETECTED mes-
sage is displayed and the Auto Stop feature does not function contact Precor Customer
Support. If the Auto Stop did not pass the test continue troubleshooting.
(Undefined variable: TRM700-16Base.ServiceManualTitle)
for error code description and troubleshooting
page 15.
6    Troubleshooting
"Club Parameter -
"Hardware Val-
and select the Auto Stop test. If the
75

Hide quick links:

Advertisement

Table of Contents
loading