8. Re-attach wire connections as follows for the 120 VAC and 240 VAC models:
a. On 120 Vac and 240 Vac treadmills, connect the blue wire from the power control
module to the L1 terminal on the LOAD side of the AC line filter and the brown
wire from the power control module to the L2 terminal on the LOAD side of the
AC line filter.
b. On 120 Vac treadmills, connect the blue wire from the input module to the L1 ter-
minal on the LINE side of the AC line filter, the brown wire from the circuit breaker
to the L2 terminal on the LINE side of the AC line filter and the green/yellow wire
to the (non-insulated) terminal mounted directly on the line filter case.
c. On 240 Vac treadmills, connect the blue wire from the circuit breaker to the L1 ter-
minal on the LINE side of the AC line filter, the brown wire from the circuit breaker
to the L2 terminal on the LINE side of the AC line filter and the green/yellow wire
to the (non-insulated) terminal mounted directly on the line filter case.
9. Set the AC input panel in its mounting position and install using the previously removed
fasteners.
10. Plug in the power cord and Switch the input power ON.
11. Verify treadmill operation per
to service.
.See Also
"Replacement Procedures" on page 29
(Undefined variable: TRM700-16Base.ServiceManualTitle)
""Operation Verification Procedure" on
5 Replacement Procedures
Line Filter Replacement
page 8" and return
56