Line Filter Replacement; About; Procedure - Precor GEN06 Series C952 Service Manual

Table of Contents

Advertisement

Line Filter Replacement

About

This procedure provides instruction to remove and replace the AC Line Filter.

Procedure

Review entire procedure before starting.
1. Set the treadmill circuit breaker to OFF and unplug the treadmill's power cord from the
AC outlet.
2. Remove the treadmill's hood.
3. Remove the two screws that fasten the AC input panel to the frame. Keep fasteners for
replacement installation.
4. Disconnect the wiring from the circuit breaker (2 blue wires on 120 Vac treadmills or 2
blue and 2 brown wires on 240 Vac treadmills) Note: The figure below is showing a 240
volt configuration.
5. Lift the AC input panel from the frame and rotate it to expose the AC input circuit
breaker screws.
6. Remove the two screws and remove the circuit breaker. Keep fasteners for replace-
ment installation.
7. Set the replacement AC line filter in its mounting position with the three terminals facing
the circuit breaker and secure with previously removed screws.