tab clip to remove.
Installation Instructions
1. Reinstall the ASL PCA
ASL PCA board into position on the bracket.
2. Reinstall the ASL PCA Bracket
Power Entry Assembly Bracket
3. Reconnect the ASL interface cable RJ11 connector, see
4. Reinstall the Power Entry Assembly bracket
fasteners. Make sure that the wire cables are not pinched or damaged during install-
ation.
5. Reinstall the hood cover, see
6. Connect the power cord and switch the ON/OFF circuit breaker ON.
7. Verify the ASL light operation:
a. Verify that the ASL light is Solid Blue. If the ALS light is Pulsing Blue, Pulsing Yel-
low, or Solid Yellow, resolve the issue and reset the ASL to Solid Blue.
8. Do the Operation Verification tests (see
to service.

E-Stop "Emergency Switch" Replacement

About

This procedure provides instruction to replace the E-Stop "Emergency Stop Switch".
Experience Series 700 Line Treadmills
board onto the ASL PCA Bracket
by pressing the tabs into the mounting slots on the
.
"Hood Cover Replacement" on
"Operation Verification" on
5 Replacement Procedures
E-Stop "Emergency Switch" Replacement
. Securely snap the
"Wire Diagram" on
and secure using the four #3 Phillips
page 56.
page 15) and return
page 79.