8. Install the actuator tube into the incline platform mounting bracket. Hold the jack screw
from turning while inserting the actuator tube into the mounting bracket. Secure with
clevis and hitch pins.
9. If the Lift Motor actuator tube has turned during the installation process (which changes
the incline reference gap distance) re-calibrate the Lift Motor, see
ibration" on
page 24.
10. Return the treadmill to the upright position.
11. Level the treadmill.
12. Install hood and all removed covers and trim.
13. Connect the power cord and Switch the input power to ON.
14. Verify the treadmill incline operation through the full range of motion. Do the
Validation - Diagnostic Tests (51765761)" on page 13
15. Verify treadmill operation (see
See Also
"Replacement Procedures" on page 29
"Lift Motor Calibration" on page 24
(Undefined variable: TRM700-16Base.ServiceManualTitle)
"Operation Verification" on
5 Replacement Procedures
Incline Lift Platform Replacement
"Lift Motor Cal-
- INCLINE TEST diagnostic test.
page 8) and return to service.