Part III: How to Program

28.0

Keypad Programming

A text keypad such as the DS7447E or
DS7447V2 Text Keypad can be used for
keypad programming. The DS7445i or
DS7445V2 LED keypads cannot be used for
keypad programming.
28.1

Installer Mode/Installer Menu

Use of the PIN might be restricted. See
"Keypad Response Options" in the
DS7200V2 Expert Programming Guide
(P/N:4998153891) for more information.
There are three methods to access the control panel's
programming mode. Choose a method from below
and follow its subsequent steps.
1.
From a text keypad:
a.
Enter the Installer PIN. The default Installer
PIN is 7890. See Installer PIN on page 63 for
instructions on changing the default Installer
PIN.
b.
Press [#][4][1] to enter the Installer's Menu.
c.
Press the [8] key to enter the programming
mode.
2.
From an Installer Keypad:
a.
Set the Installer Keypad address to 0 (zero).
b.
Connect the Installer Keypad to the control
panel. See Installer Keypad on page 33 for
instructions.
c.
Close the Installer Switch.
d.
Enter the Installer PIN.
e.
Press [#][4][1] to enter the Installer's Menu.
f.
Press the [8] key to enter the programming
mode.
3.
Without an Installer's PIN:
a.
Remove all power from the control panel
(Mains and standby battery).
b.
Close the Installer Switch.
c.
Connect the Installer Keypad to the control
panel if you are using an Installer Keypad.
d.
Restore all power to the control panel.
e.
Locate the keypad displaying the Installer
Menu.
f.
Press the [8] key.
Page 38
P/N: 4998152533-02
PART III: HOW TO PROGRAM
Copyright  2007 Bosch Security Systems, Inc.
28.2

Expert/Installer Programming Modes

• Installer Programming Mode: Installer
Programming Mode is the control panel's default
programming mode. This mode allows the installer
to access only a subset of the available
programming parameters. Installer Programming
Mode follows through the addresses shown in this
document.
• Expert Programming Mode: When the control
panel enters the Expert Programming Mode, all of
the available programming parameters can be
accessed. The DS7200V2 Expert Programming
Guide (P/N: 4998153891) covers the expert set of
parameters and provides instructions on entering
Expert Programming Mode.
28.3

Parameter Addresses

Data for each parameter is stored at one or more
addresses. Special addresses identified as option
parameters allow you to set several options at a
single address.
There are two parts to every address displayed
across the keypad's top line:
• Adr: XXXX: The number following "Adr" indicates
the current address displayed.
• D=X: "X" indicates the data digit selection for the
address currently displayed.
Adr: 0000
To view a specific address, enter the 4-digit address
number and then press [#].
For example, to go to Address 0221, press the
following keys in this order: [0][2][2][1][#].
Leading zeroes can be omitted. Pressing [2][2][1][#] is
the same as pressing [0][2][2][1][#].
Adr: 0000
0221
To scroll forward one address at a time, press [#]. To
scroll back one address at a time, press [*].
D=0
D=0