Keypad (Command Center); Keypad (Command Center) Assignment - Bosch D9412GV3 Program Entry Manual

Table of Contents

Advertisement

D9412GV3/D7412GV3 | Program Entry Guide | 2.0
A# Entry Warning
Default:
Yes
Selection:
Yes or No
Yes
Pulse the alarm output for the last 10
sec of the Entry Delay time.
No
Do not pulse the Alarm Bell output
during the Entry Delay time.
When enabled, the Alarm Bell output pulses on and
off every 2 sec for the remaining 10 sec of the Entry
Delay time.
For SIA CP-01 Compliance
A# Entry Warning must be set to Yes.
Cmd Center
SDI Address (CC#)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Enter the keypad (CC) number for the SDI address you are programming. This number corresponds to the DIP
switch address settings shown.
Switch 5: On=Encoding Tone On (default), Off=Encoding Tone Off
The D1255 can be addressed as 1 through 16. The D1260 can be addressed only as 1 – 8.
Bosch Security Systems, Inc. | 10/11 | F01U170807-02
Panel and Area Wide Parameters
1
2
ON
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
ON
OFF
OFF
OFF
Get other manuals https://www.bkmanuals.com
2.9

Keypad (Command Center)

This programming module contains three
programming categories: Cmd Cntr Assignment,
Area Text, and Custom Function.
2.9.1

Keypad (Command Center) Assignment

This programming category assigns a keypad to an
area and determines if the keypad is supervised. The
keypads are connected to the control panel using a
two-wire serial data interface (SDI) bus.
This bus can support up to sixteen supervised
keypads, each with its own unique keypad address
(CC) and corresponding DIP switch address settings.
If the keypads are not supervised, you can install
multiple keypads with the same DIP switch address
setting for up to 32 unsupervised keypads.
Enhanced keypads (D1260 Series) and standard
keypads (D1255 Series) cannot share the same SDI
Address.
DIP Switch Setting
3
4
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
ON
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
EN | 50
5
6
--
ON
--
ON
--
ON
--
ON
--
ON
--
ON
--
ON
--
ON
--
ON
--
ON
--
ON
--
ON
--
ON
--
ON
--
ON
--
ON

Hide quick links: