SPIO Card Interfaces
Pin
7
8
Central Office Alarm Interface
The Central Office (CO) alarm interface is a 10-pin Molex connector supporting three dry-contact relay
switches. The three normally closed (NC) relays can support normally open (NO) or NC devices.
Table 94: SPIO CO Alarms Interface Pinout
Pin
1
2
3
4
5
6
7
8
9
10
The 8-foot (2.4 meter) CO alarm cable shipped with the chassis supports redundant SPIO card installations.
This "Y" cable has two Molex connectors on one end that are keyed to fit into the CO Alarm interfaces in one
direction only. Each connector mates with one of the side-by-side SPIO cards. On the opposite end is a 9-pin
terminal block that you can mount to the telco cabinet or equipment rack frame.
ASR 5000 Installation Guide
238
10Base-T 10Mbps Cat3
Not used
Not used
Signal
Major Alarm - Normally closed
Major Alarm - Common
Major Alarm - Normally open
Minor Alarm - Normally closed
Minor Alarm - Common
Minor Alarm - Normally open
Critical Alarm - Normally closed
Critical Alarm - Common
Critical Alarm - Normally open
Not used
100Base-Tx 100Mbps Cat5
Not used
Not used
Technical Specifications
1000Base-Tx 1Gbps Cat5+
BI DD+
BI DD-