Connecting the PFU to the Power Source
Verify that the power source from the fuse panel is OFF before attaching power cables to the PFU(s) installed
in the chassis.
Spannungsversorgung abschalten vor Anschluss der Kabel an die Netzteile, um einen elektrischen Schlag zu
vermeiden.
Step 1
Flip the circuit breaker actuator on the PFU installed in the bay labeled Power Filter Unit 1 to the OFF position. If the
circuit breaker on the PFU is equipped with a locking clip, lock the circuit breaker in place by moving the breaker's
locking clip to the right until the clip's inside tang is recessed in the breaker's actuator opening.
Step 2
Remove the plastic cover from the power terminals with a #2 Phillips head screw driver.
Step 3
Use a 9/16-inch nut driver or socket wrench to remove the nuts and the lock-washers from each of the four terminals.
Step 4
Connect the lug attached to the power return cable to the PFU:
a) Insert the lug over the two terminals labeled RTN. These are the two top terminals on the PFU.
b) Secure the lug to the RTN terminals with two of the four washers and two of the four nuts that you removed in step
3. The nuts should be torqued to 50 in-lb. (5.65 N-m).
Step 5
Connect the lug attached to the power feed cable to the PFU:
a) Insert the lug over the two terminals labeled -VDC. These are the two bottom terminals on the PFU.

ASR 5000 Installation Guide

130
Cabling the Power Filter Units