During installation, maintenance, and/or removal, wear grounding wrist straps to avoid ESD damage to
Caution
the components. Failure to do so could result in damage to sensitive electronic components and potentially
void your warranty.
Step 1
Re-install the PFUs into the chassis.
a) Locate the PFU bays at the lower-rear of the chassis. The bays are labeled from left to right Power Filter Unit 1 and
Power Filter Unit 2.
b) Slide the PFU assembly into the PFU bay labeled Power Filter Unit 1 until it is flush against the chassis.
c) Use a Phillips #2 screwdriver to tighten each of the four screws on the PFU to secure it to the chassis.
d) Re-install the second PFU in the PFU bay labeled Power Filter Unit 2 by repeating step b and step c.
Step 2
Re-install the lower fan tray assembly into the chassis.
Re-Installing Chassis Sub-components