Saeco Cristallo 600 EVO Use And Maintenance page 74

D.a. fs 400 2015; d.a. fs 600 2015
Table of Contents

Advertisement

English
PAIRING TABLE
Channel
1
2
3
4
5
6
7
Settings
0
1
2
3
4
Stop sugar
CHANGE TABLE
No.
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Key:
L = channel with the lowest coin value below the minimum level
M = channel with the medium-low coin value below the minimum level
HL = channel with the medium-high coin value below the minimum level
HH = channel with the highest coin value below the minimum level
STATISTICS
Prices
All unit supplies
All supplies will be
will be counted in
provided at the
the unit code
unit code price.
statistics.
74
Payment system
Coin validator
Coin validator
Coin validator
Coin validator
Coin validator
Coin validator
Cancelling machine
SUGAR TABLE
Sugar in beverage without
preselection
Without sugar
1
2
3
4
Without sugar
Description
L or M or HL or HH
L or M
HL or HH
L or HH
L
M
HL
L and HH
HL and HH
L and M
L and M and HL and HH
L and HL or L and HH
L or HL and HH
HH
L and M and HL
Never (change always available)
STATISTICS TABLE
Capacity
Unit independence will
amount to the sum
of the individual
independence values
of the unit spirals.
Sugar in beverage with
preselection
Quantity preselected
Quantity preselected
Quantity preselected
Quantity preselected
Quantity preselected
Without sugar
Errors
Errors reported concerning one of the unit motors will be recorded as individual
motor errors.
The faulty motor will be disabled and will not participate in unit function.
The unit will remain operative all the time at least one motor continues to work
correctly.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cristallo 400 evo

Table of Contents