Saeco Cristallo 600 EVO Use And Maintenance page 68

D.a. fs 400 2015; d.a. fs 600 2015
Table of Contents

Advertisement

English
DISPLAY
5.8.9.
Alarm Temperature
...
5.8.10.
Alarm timeout
...
5.8.11.
Refill allarm timeout
...
5.9.
Door Heaters
...
5.10.
Show temperature
...
5.11.
Photocells
5.11.1.
Photocell Enabled
5.11.2.
Max motor overtime
5.11.3.
Disable selection
5.11.4.
Photoelectric cells block
5.11.5.
Credit Return
5.12.
Capacity ctrl enabled
68
[° C] "food" alarm temperature [Range: 3 .. 30].
The machine deactivates the selections set as food if the internal temperature exceeds this
value for a time longer than the value set at the following option (Error 75).
This error signal can be reset by pressing button 5 (black) on the 5-button keypad or by
selecting product 997 within 20 seconds of closing the door or switching the vending
machine on.
Once these first 20 seconds have passed, selecting "997" will have no effect.
[min] Number of minutes allowed when the air temperature is higher than the alarm
temperature.
If the temperature exceeds the limit longer than the time set, the machine deactivates the
selections set as food [Range 0 .. 60].
[min] When the opening of a door is detected or if the button 5 on the 5-buttons keypad is
pushed, the time set here will replace the usual timeout set by the previous option. [Range
0 .. 120].
This prevents the machine from entering error mode after product supply operations.
Please, remember that the machine must be supplied with products already at the correct
temperature for storage.
NO = door heaters OFF
YES = door heaters ON
Enables / disables the visualization of the temperature on the display during normal
operation.
Enables / disables the photoelectric cell system.
[x100 ms] Period of extension of the spiral motor activation, when the fall of the product is
not detected. [Range 0 .. 5 ].
Max. number of consecutive photoelectric cell errors in a selection, before this one is
deactivated.
If it is set to 0, the deactivation will never be carried out.
Max. number of consecutive photoelectric cell errors before the system of detection of the product fall is
deactivated.
If it is set to 0, the system will never be disabled.
(NOTE: typing 999 on the keypad, the display of the vending machine will show for a few seconds a message
concerning the status of the photoelectric cell system - see the section - Display of Special Information).
Activates/ deactivates the return of the product cost to the user, if the fall of the product
has not been detected.
To prevent a customer from selecting a product of which the machine has run out, each
spiral can be enabled to supply only a preset number of products.
Description