3. WIRING
2) For single-phase 100V to 120VAC/single-phase 230VAC power supply
Power
Single-phase
100 to 120AC
or
single-phase
230VAC
Note: Not provided for single-phase 100V to 120VAC.
(3) Timing chart
(4) Emergency stop
To ensure safety, always install an external emergency stop switch across EM1-SG. By disconnecting
EM1-SG, the dynamic brake is operated to bring the servo motor to a sudden stop. At this time, the
display shows the servo emergency stop warning (E6).
During ordinary operation, do not use the external emergency stop signal to alternate stop and run.
Doing so may shorten the life of the servo amplifier.
NFB
Emergency stop
Servo on
ON
3-phase power supply
OFF
ON
Base circuit
OFF
Servo on command
ON
(from controller)
OFF
Power ON Timing Chart
Emergency stop
OFF
RA
MC
L1
L2
L3 (Note)
L11
L21
EM1
SG
VDD
COM
Son accepted
(1s)
Servo amplifier
VDD
COM
EM1
SG
3 - 31
ON
MC
MC
SK
Servo amplifier
MR-J2- B
10ms