6. OPTION AND AUXILIARY EQUIPMENT
2) Bus Cable
CAUTION
For the optional bus cable, pins not used normally are connected. When the customer fabricates the bus
cable, pins without signals need not be connected. The total length of the bus cables in a single system is
up to 30m.
MR-J2HBUS05M-A
MR-J2HBUS1M-A
MR-J2HBUS5M-A
Controller side
connector
PCR-S20FS (Connector)
PCR-LS20LA1 (Case)
LG
1
LG
11
RD
2
RD*
12
TD
4
TD*
14
LG
5
LG
15
6
EMG
EMG*
16
SD
20
When you fabricate the bus cable, connect it correctly.
Otherwise, misoperation or explosion may occur.
Servo amplifier side
connector
10120-6000EL (Connector)
10320-3210-000 (Shell kit)
1
11
2
12
4
14
5
15
7
17
Plate
Servo amplifier side
connector
10120-6000EL (Connector)
10320-3210-000 (Shell kit)
LG
1
LG
11
RD
2
RD*
12
3
13
TD
4
TD*
14
LG
5
LG
15
6
16
EMG
7
EMG*
17
8
18
BT
9
19
10
20
SD
Plate
6 - 10
MR-JHBUS05M-A
MR-J2HBUS1M-A
MR-J2HBUS5M-A
Servo amplifier side
connector
10120-6000EL (Connector)
10320-3210-000 (Shell kit)
1
11
2
12
3
13
4
14
5
15
6
16
7
17
8
18
9
19
10
20
Plate