6. OPTION AND AUXILIARY EQUIPMENT
(2) Standard encoder cable
The specifications and connection of each cable are indicated below. A fabricated cable should be as
specified in the following table or equivalent and connected correctly.
2
Core Size [mm
]
Pair
0.08 7
0.08 10
0.2 7
0.3 7
Note: d is as shown below.
2
Core Size [mm
]
Pair
0.2 6
Note: Junkosha make, purchased from Toa Electric
For the control signal connector, connect the external conductor of the shielded cable to the ground plate
securely as shown below.
a. Termination of external conductor
External conductor
Strip the sheath.
b. Fitting of the ground plate
Core Insulation Sheath OD
(Note) d [mm]
0.9 to 1.27
Conductor
Insulation sheath
Characteristics of One Core
Structure
Conductor
[pcs./mm]
resistance[ /km]
40/0.08
105 max.
Sheath
Screw
Ground plate
Recommended Cable Model
UL20276
AWG28 7pair (BLACK)
UL20276
AWG28 10pair (BLACK)
UL20276
AWG24 7pair (BLACK)
UL20276
AWG22 7pair (BLACK)
d
Sectional view of core
Recommended Cable Model
(Note)
A14B2343
Core
Pull back the external conductor to cover the sheath
Screw
Cable
6 - 7
Cable Type
Standard encoder cable
Communication cable
Bus cable
Standard encoder cable
Standard encoder cable
Cable Type
Flexing, long-life
encoder cable
Sheath
External conductor