2. OPERATION
2 - 5 Test operation mode
CAUTION
By using a personal computer and the set-up software (MRZJW3-SETUP41E or later), you can execute
jog operation, positioning operation, motor-less operation and forced output without connecting the
motion controller.
(1) Test operation mode list
Test Operation Mode
Jog operation
Positioning operation
1. The test operation mode is designed for servo operation confirmation and not for
machine operation confirmation. Do not use this mode with the machine. Always
use it with the servo motor alone.
2. If an operation fault occurred, use the external emergency stop (EM1) to make a
stop.
Jog operation can be performed without using the servo system controller. Use this
operation with the external emergency stop reset. This operation may be used
independently of whether the servo is on or off and whether the servo system controller
is connected or not.
Exercise control on the jog operation screen of the set-up software.
1) Operation pattern
Speed [r/min]
Acceleration/deceleration time constant [ms]
2) Operation method
Operation
Forward rotation start
Reverse rotation start
Stop
Positioning operation can be performed without using the servo system controller. Use
this operation with the external emergency stop reset. This operation may be used
independently of whether the servo is on or off and whether the servo system controller
is connected or not.
Exercise control on the positioning operation screen of the set-up software.
1) Operation pattern
Travel [pulse]
Speed [r/min]
Acceleration/deceleration time constant [ms]
2) Operation method
Operation
Forward rotation start
Reverse rotation start
Pause
Description
Item
Screen Control
Press [Forward (G)] button.
Press [Reverse (R)] button.
Press [Stop (O)] button.
Item
Screen Control
Press [Forward (G)] button.
Press [Reverse (R)] button.
Press [Pause (O)] button.
2 - 16
Initial Value
Setting Range
200
0 to max. speed
1000
1 to 20000
Initial Value
Setting Range
100000
0 to 9999999
200
0 to max. speed
1000
1 to 50000