6. OPTION AND AUXILIARY EQUIPMENT
(3) Cable clamp fitting (AERSBAN- SET)
Generally, the earth of the shielded cable may
only be connected to the connector's SD terminal.
However, the effect can be increased by directly
connecting the cable to an earth plate as shown
below.
Install the earth plate near the servo amplifier for
the encoder cable. Peel part of the cable sheath to
expose the external conductor, and press that part
against the earth plate with the cable clamp. If
the cable is thin, clamp several cables in a bunch.
The clamp comes as a set with the earth plate.
Outline drawing
Earth plate
2- 5(0.20) hole
installation hole
6
(Note)M4 screw
(0.24)
Note: Screw hole for grounding. Connect it to
the earth plate of the control box.
17.5(0.69)
22(0.87)
35(1.38)
Type
A
100
AERSBAN-DSET
(3.94)
70
AERSBAN-ESET
(2.76)
Strip the cable sheath of
the clamped area.
Clamp section diagram
L or less
B
C
Accessory Fittings
86
30
clamp A: 2pcs.
(3.39)
(1.18)
56
clamp B: 1pc.
(2.20)
6 - 19
cutter
cable
Cable
Cable clamp
(A,B)
External conductor
Clamp section diagram
10(0.39)
Clamp Fitting
A
B
Earth plate
[Unit: mm]
([Unit: in.])
L
70
(2.76)
45
(1.77)