Omron C200HW-CLK21 Operation Manual page 62

Controller link units
Hide thumbs Also See for C200HW-CLK21:
Table of Contents

Advertisement

Data Links Procedures
Chain Type
Contents
a. Set the data link mode
to automatic.
b. 1:N creation
c. Set the area
d. Set the data link start
word
e. Set the number of
common send words
per master node
f.
Set the number of
send and receive
words per node
g. Set the first data link
status word
h. Set the nodes to par-
ticipate in the data
links.
Note For automatic data link creation with 1:N allocations, use the CX-Net
in CX-Programmer version 3.2 or higher.
8. Start the data links.
Contents
Start the data links.
Note Data link Start/Stop Bit (N= unit number):
CS/CJ Series:
C200HX/HG/HE:
CVM1/CV Series:
CQM1H Series:
9. Stop the data links.
Contents
Stop the data links.
Note Data link Start/Stop Bit (N= unit number):
CS/CJ Series:
Method
Use Support Soft-
Data link startup node
ware for the PLC
only
including Program-
The node that is used
ming Console (see
to start the data link is
note).
called the startup
node. It is necessary
to decide beforehand
which node will be
the startup node.
Data link startup node
only
Method
Switch the Data link
Data link startup node
Start/Stop Bit (listed
(The Start Bit can be
below) from OFF to
turned ON in more
ON using either the
then one node to
Programming Device,
make sure the data
or the user program.
links start even when
the startup node is
down.)
Word 0 of DM30000 + 100
AR 0700 (operating level #0),
AR 0704 (operating level #1)
Word 0 of DM 2000 + 100
AR 0700
Method
Switch the Data link
Any node that is active
Start/Stop Bit (listed
in the data link
below) from OFF to
ON using either the
Programming Device,
or the user program.
Word 0 of DM30000 + 100
Section 2-1
Nodes
Page
113
141
Nodes
Page
153
N
N
Nodes
Page
153
N
39