Neutral Diode (Nc700X/Xa/S/Sa); Starter Relay (Nc700Xd/Sd) - Honda NC700XA Service Manual

Hide thumbs Also See for NC700XA:
Table of Contents

Advertisement

dummyhead
dummyhead
ELECTRIC STARTER

NEUTRAL DIODE (NC700X/XA/S/SA)

INSPECTION
Remove the maintenance lid (page 21-6).
Open the fuse/relay box cover and remove the neutral
diode [1].
Check for continuity between the neutral diode
terminals.
When there is continuity, a small resistance value will
register.
If there is continuity, in direction shown by the arrow,
the neutral diode is normal.

STARTER RELAY (NC700XD/SD)

INSPECTION
Remove the maintenance lid (page 21-6).
Open the fuse/relay box cover and remove the START
RELAY [1].
Connect an ohmmeter to the START RELAY [1]
connector terminals.
Connect a 12 V battery to the START RELAY connector
terminals as shown.
There should be continuity only when 12 V battery is
connected.
If there is no continuity only when the 12 V battery is
connected, replace the START RELAY.
6-12
A
A
C
B
[1]
[1]
B
C
[1]