Note:
Ensure that the Harnesses are reinstalled properly
as illustrated.
(48) Reinstall the Harness Cover 3 (4921).
(49) Reinstall 1 Black Screw.
<Install the Fuser Unit>
(50) Install the Fuser Unit.
(51) Secure 2 Screws.
(52) Connect the Harness.
(53) Reinstall the Harness Cover 2 (4813).
(54) Reinstall 1 Screw.
(55) Close the Upper Right Side Cover.
Note:
When reinstalling the Fuser Belt Unit, reset the PM
Counter.
Perform "F8-26" Fuser Belt Counter Reset. (F7-
02-65/85/86 Fuser Belt Remain Count is also
initialized by this operation)
<Replacing the Complete Fuser Unit>
(56) Remove all tapes, and cushioning materials.
(57) Remove the Shipping Cover.
92