12.1.3.1.2. Feeding System

[1]
[2]
[5]
[4]
Ver. 1.1
Fig. 3-016
Fig. 3-017
Gear
Timing Belt
Gear
Fig. 3-18

2-1. Removing the Stapler Unit

(1) Open the Front Door [1].
(2) Slide out the Stapler Unit [3] while pressing the
Stopper Lever [2].
[3]
Caution:
Do not remove the stapler from the Stapler Frame
Shaft. If removed, the position where the Staple
Driver (Lower Unit of the Stapler) [4] shoots
staples will shift from the position where the Staple
Clincher (Upper Unit of the Stapler) [5] receives
Staples.

2-2. Adjusting the Stapler Phase

When the Gears or Timing Belt at the front of the
Stapler is replaced or removed for some reason, the
staple shooting timing of the Staple Driver (Lower Unit
of the Stapler) does not match the staple bending
timing of the Staple Clincher (Upper Unit of the
Stapler). Adjust the Stapler phase following the
procedure described below.