Starting System
Starter Overhaul (cont'd)
Starter Brush Inspection
11. Measure the brush length. If it is not w i t h i n the
service limit, replace the armature housing
assembly (M/T), or the brush holder assembly (A/T).
Brush Length
Standard (New):
M/T:
1 5 . 0 - 1 5 . 5 m m ( 0 . 5 9 - 0 . 6 1 in.)
A / T :
1 5 . 8 - 1 6 . 2 mm ( 0 . 6 2 - 0 . 6 4 in.)
Service Limit:
M/T:
10.0 mm (0.39 in.)
A / T :
11.0 mm (0.43 in.)
Starter Field Winding Test (M/T)
12. Check for continuity between the brushes (A). If
there is no continuity, replace the armature
housing (B).
A
B
13. Check for continuity between each brush (A) and
the armature housing (B). If there is continuity,
replace the armature housing.
Starter Brush Holder Test
14. Check that there is no continuity between the ( + )
brush holder (A) and ( —) brush holder (B). If there
is no continuity, replace the brush holder assembly.
M/T:
4-14