Using the Self-Diagnosing Function

With the switch in the ON position,
press the key for a period of approximately
5 seconds until a beep sounds.
Self-diagnosing Mode 1:
Mode 1 starts with two long beeps as the tachometer needle
points to 5,000 rpm.
The needle then returns to 0 and operation automatically
proceeds to Mode 2.
Self-diagnosing Mode 2:
This Mode displays the number of engine operating hours on
the tachometer in combination with the three warning
indicators.
Refer to Engine Operating Hours Table.
With the key in the On position, press for approximately
1 second until the beep sounds to enable Mode 3.
Self-diagnosing Mode 3:
This Mode displays after one short beep sounds, the fault location and
fault log for first incident at a time using the tachometer in combination
with the three warning indicators.
Refer to the Fault Indication Table.
The locations and logs for successive faults can be viewed by pressing
for approximately 1 second until the beep sounds with the key switch in
the ON position.
Once Mode 3 has been used to display the location and log information
for all recorded faults, the display goes blank.
Pressing the key switch at this point will repeat display of location and log
information from the first fault.
Note that nothing is displayed if there is currently no recorded fault
information.
(Tachometer and warning indicators are inactive.)