Paper Transfer

After installing a new ID sensor board

Do the following adjustment after installing a new ID sensor board.
1.
Plug in and turn on the main power switch of the machine
2.
Enter the SP mode.
3.
Enter all correction coefficients [A] for ID sensor with the SP modes referring to the barcode
sheet provided with the new ID sensor board.
For example, enter "1.2" with SP3-331-046.
4.
Exit the SP mode.